Taifno manufactures virgin PTFE laboratory funnels for corrosive liquid transfer, trace-analysis sample filtration, HF and aqua regia handling, and high-temperature laboratory workflows. Standard top diameters range from 30mm to 150mm, with custom sizes, stem dimensions and machined configurations available. Established in 2012, Taifno supports international buyers with factory quotations, samples, dimensional confirmation and application-specific documentation.
    Virgin PTFE Laboratoryware Manufacturer

    PTFE Funnel Manufacturer for Corrosive Liquid Transfer and Laboratory Filtration

    Taifno manufactures standard and custom virgin PTFE laboratory funnels for trace analysis, corrosive chemical handling, sample filtration and high-temperature laboratory workflows.

    A PTFE funnel is a laboratory vessel made from 100% PTFE through isostatic molding or machining. It is an ideal alternative to glass and ordinary plastic funnels, particularly suitable for highly corrosive liquid transfer, trace analysis sample filtration, and high-temperature digestion where vessel purity is critical.

    Virgin PTFE laboratory funnel manufactured for corrosive liquid transfer and trace analysis filtration
    Factory-Direct Supply

    Taifno was established in 2012 and has 14+ years of PTFE manufacturing experience. Standard 30mm to 150mm funnels and special made-to-order sizes are available for laboratories, distributors and industrial procurement teams.

    Material
    100% Virgin PTFE
    Standard Sizes
    30-150mm
    Continuous Temperature
    -200°C to +250°C
    Manufacturing
    Isostatic Molded or Machined
    Manufacturer
    Established in 2012

    Key Features of Virgin PTFE Laboratory Funnels

    Material properties for corrosive chemical transfer, filtration and contamination-sensitive laboratory work.

    Resists all chemicals except molten alkali metals and fluorine; stable against strong acids, alkalis, aqua regia, and all organic solvents
    No leaching or extraction, suitable for trace and ultra-trace analysis
    Wide temperature range: -200°C to +250°C continuous, short-term up to 300°C on hot plates
    Non-stick surface: lowest COF, liquids and powders do not adhere, easy to clean
    Non-absorbent: water absorption <0.01%
    Autoclavable at 121°C
    Physiologically inert: non-toxic

    PTFE Funnel vs Glass Funnel: Why Upgrade?

    Compare material compatibility, contamination risk, temperature performance and service durability before purchasing laboratory funnels.

    Comparison Glass Funnel PTFE Funnel Customer Value
    Chemical Resistance Not HF-resistant, not strong alkali-resistant; may leach metal ions Resists all chemicals (except molten alkali metals and fluorine) Suitable for more corrosive samples
    Metal Blank High (contains Na, Ca, Al, etc.) Extremely low, no leaching More reliable trace analysis data
    Temperature Breaks under uneven heating -200°C to +250°C (short-term 300°C) Suitable for extreme temperature experiments
    Non-Stick Liquids/powders stick Lowest COF, non-stick surface No sample residue, easy to clean
    Drop Resistance Fragile Durable, no breakage More durable, reduced replacement cost
    Autoclavable Yes, but fragile Autoclavable at 121°C Suitable for sterile experiments
    Best For Routine experiments, non-corrosive samples Trace analysis, HF digestion, aqua regia, semiconductor Application-specific material selection

    PTFE Funnel Technical Specifications

    Confirm the material grade and required compliance documents with Taifno before ordering for regulated applications.

    Parameter Value Note
    Material 100% Virgin PTFE Isostatic molded or machined
    Color Opaque white Standard PTFE appearance
    Continuous Temp -200°C to +250°C Short-term up to 300°C on hot plates
    Short-Term Max 300°C On hot plates
    Molten Alkali/Fluorine Not suitable Media requiring separate compatibility review
    Coefficient of Friction One of the lowest (PTFE property) Among the lowest of solid materials
    Water Absorption <0.01% Almost non-absorbent
    Autoclavable Autoclavable at 121°C Steam sterilization
    Certifications FDA 21 CFR 177, REACH, BSE/TSE free Food grade and pharmaceutical grade available; documentation must be specified when ordering

    Standard PTFE Funnel Sizes

    Standard top diameters range from 30mm to 150mm. Custom top openings, stems, heights and shapes can be evaluated.

    Size Top OD (mm) Stem OD (mm) Height (mm)
    30mm 30 8 50
    50mm 50 10 85
    70mm 70 12 110
    80mm 80 To be confirmed To be confirmed
    100mm 100 14 170
    120mm 120 To be confirmed To be confirmed
    150mm 150 16 220
    Custom PTFE funnel sizes: Size range: 30mm to 150mm, special sizes customizable. Send the required top OD, stem OD, height, tolerance and quantity for dimensional confirmation and a factory quotation.

    Core Advantages and Customer Value

    Key reasons laboratories and industrial buyers specify PTFE funnels instead of ordinary glass or plastic laboratoryware.

    Universal Chemical Resistance Resists all chemicals except molten alkali metals and fluorine; suitable for strong acids, alkalis and aqua regia. Customer benefit: one funnel for almost all ICP-MS analysis and cryogenic preservation.
    Ultra-Low Blank No leaching or extraction, with extremely low metal blank values. Customer benefit: more reliable trace analysis data.
    Wide Temperature Range Continuous use from -200°C to +250°C, with short-term use up to 300°C. Customer benefit: suitable for extreme-temperature experiments.
    Non-Stick and Easy to Clean Lowest COF, so liquids and powders do not adhere easily. Customer benefit: simpler sample transfer and cleaning.
    Durable Construction Isostatic molded pure PTFE provides uniform wall thickness and improved drop resistance. Customer benefit: reduced replacement and product-loss costs.
    Autoclavable Autoclavable at 121°C when the correct heating and cooling procedure is followed. Customer benefit: suitable for sterile applications.
    FDA and REACH Options Material grades with relevant FDA 21 CFR 177 and REACH documentation can be specified. Customer benefit: supports food and pharmaceutical procurement requirements.

    PTFE Funnel Applications

    PTFE funnels are selected for applications where chemical compatibility, low contamination and reliable sample transfer are critical. Explore additional PTFE application guidance.

    Semiconductor
    Ultra-pure chemical transfer, wafer etching and acid filtration
    Key requirement: ultra-low metal contamination
    Environmental Testing
    Water heavy-metal analysis sample filtration and soil digestate transfer
    Key requirement: no metal leaching
    Pharmaceutical
    API solution filtration and USP-compliant experiments
    Key requirement: specified compliance documentation
    Food Testing
    Sample preparation for heavy-metal and trace-element analysis in food
    Key requirement: FDA-compliant material grade and non-toxic construction
    Chemical and Petrochemical
    Transfer and filtration of strong acids, alkalis, aqua regia and HF samples
    Key requirement: compatibility with corrosive media
    Research Institutes
    Trace-analysis sample preparation, new-material synthesis and fuel-cell R&D
    Key requirement: high purity and stable performance
    Defense and Nuclear
    Radioactive sample handling and nuclide analysis
    Key requirement: corrosion resistance and application-specific technical review

    Important PTFE Funnel Usage Notes

    Observe the applicable laboratory safety procedure and verify chemical compatibility for the actual medium, concentration, temperature and contact time.

    Use with Wire Gauze Do not place directly on flame. Use with wire gauze.
    Avoid Molten Alkali Metals Molten sodium, potassium and similar media corrode PTFE.
    Avoid Fluorine Gas Fluorine and chlorine trifluoride react with PTFE.
    Hot Plate Use Short-term use up to 300°C on hot plates.
    Autoclaving Autoclavable at 121°C; avoid rapid cooling to prevent deformation.
    Customizable Special sizes and shapes are available for made-to-order laboratory funnel requirements.

    Information Required for a PTFE Funnel Factory Quote

    Providing complete application and dimensional information helps Taifno prepare an accurate custom PTFE funnel quotation.

    Funnel Dimensions Provide the required top OD, stem OD, height and any dimensional tolerance requirements.
    Order Quantity State the sample quantity, trial order, annual purchasing volume and requested delivery schedule.
    Chemical Medium Identify the liquid, concentration and expected contact time for material compatibility review.
    Operating Temperature Provide the normal and maximum temperature, heating method and sterilization conditions.
    Filtration Setup Describe the filter medium, receiving vessel, support method and required flow characteristics.
    Documentation Specify required FDA, REACH, BSE/TSE, inspection, dimensional or material documentation.

    Why Choose Taifno as Your PTFE Funnel Manufacturer?

    Taifno was established in 2012 and has 14+ years of PTFE manufacturing experience. We support laboratories, research institutes, distributors and industrial buyers requiring standard PTFE funnels, custom laboratory funnels and application-specific PTFE components.

    14+ Years of PTFE Manufacturing Experience Established in 2012, Taifno has practical experience in PTFE molding, machining, dimensional control and laboratory-product manufacturing.
    Factory-Direct Supply Direct communication with the manufacturer supports clearer technical review, stable production and efficient quotation handling.
    Isostatic Molding and Precision Machining Different manufacturing processes can be selected according to funnel size, geometry, tolerance and order requirements.
    Standard and Custom Sizes Standard top diameters range from 30mm to 150mm, while special top openings, stems, heights and shapes can be evaluated.
    Material and Dimensional Control Raw-material records, production information and dimensional inspection can support purchasing and quality-control requirements.
    Application Selection Support Taifno can review the chemical medium, temperature, filtration setup and compliance requirements before production.
    International Buyer Support Samples, export-order communication, custom drawings and required documentation can be coordinated for overseas buyers.
    24-Hour Inquiry Response Technical questions, sample requests and factory quotation inquiries are normally answered within 24 hours.

    PTFE Funnel Frequently Asked Questions

    Material-selection and purchasing answers for laboratory managers, distributors and industrial procurement teams.

    What is the difference between PTFE funnels and glass funnels? When should I use PTFE funnels?

    PTFE funnels offer extremely low metal blank values (no leaching), resistance to all chemicals (including HF and aqua regia), non-stick surface (lowest COF), and durability. Glass funnels are corroded by HF, strong alkalis, and leach metal ions. Choose PTFE funnels for: trace/ultra-trace analysis, HF digestion, aqua regia handling, semiconductor chemical analysis, extreme temperature experiments. Choose glass funnels for: routine experiments, non-corrosive samples, cost-priority applications.

    What is the operating temperature range for PTFE funnels? Can they be heated?

    Temperature: Continuous -200°C to +250°C, short-term up to 300°C on hot plates. Yes, can be heated, but always use a wire gauze. Do not expose directly to open flame. PTFE softens and deforms above 250°C. Do not exceed the temperature limit.

    Can PTFE funnels be used for food or pharmaceutical sample testing?

    Yes. PTFE is non-toxic and physiologically inert, meeting FDA 21 CFR 177 and REACH standards. PTFE funnels do not leach or adsorb, ensuring no sample contamination, and are suitable for quality testing and R&D in food and pharmaceutical industries. Please specify FDA-compliant grade and the required compliance documents when ordering.

    Can PTFE funnels be autoclaved?

    Yes. PTFE funnels are autoclavable at 121°C. Allow slow cooling after autoclaving to avoid deformation from rapid temperature changes. Sterilization temperature must not exceed PTFE's continuous service temperature limit.

    Request a Factory Quote for PTFE Laboratory Funnels

    Send your required top diameter, stem diameter, height, quantity, chemical medium, operating temperature and documentation requirements for a factory quotation.

    Phone / WhatsApp: +86-18057455621

    Email: Tommy.xiao@taifno.com

    Standard and Custom PTFE Funnels

    Request dimensional confirmation, a test sample, material documentation or pricing for bulk PTFE laboratory funnels.

    Request a Quote or Sample
    Send Inquiry
    Contact Info
    X
    We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
    RejectAccept